Weather changes. AVITOR doesn't.
AVITOR is a smart hydronic system: one machine that cools your rooms and heats your water at the same time. Rooms from 16 to 30 °C, chilled water down to 7 °C, hot water up to 55 °C, with up to 40% less power than a separate AC and geyser.
- Cooling and hot water together, 24x7, from one refrigerant circuit
- Free hot water from the heat your AC would throw outside
- Five models from 3 to 16 TR for homes, hotels, hospitals, offices, industry and defence
- No gas inside your home: only water
- 3-year comprehensive warranty with 24x7 technical support
You pay your AC to throw heat outside. Then pay your geyser to make it again.
Same energy. Paid for twice. 570 L of water warmed every hour, with the energy a standard setup throws away.
AVITOR stops you paying twice. Free hot water.
While your rooms are cooled, their heat becomes hot water, stored in the tank. No outdoor units crowding your walls. No separate water heaters anywhere.
AVITOR is not an AC. It is a modular chiller: one outdoor machine that makes chilled water and hot water at the same time. Your indoor units turn the chilled water into cool air, and the hot water goes to your taps.
- One machine: Replaces the outdoor units, the geysers and the separate controls.
- Two jobs at once: Chilled water at 7 °C and hot water up to 55 °C from one refrigerant circuit.
- Heat put to use: The heat a standard VRF throws outside is claimed back for hot water.
What you get
- 16–30 °C Room temperature: Cool air down to 16 °C, warm air up to 30 °C
- 7 °C Chilled water: Down to
- 55 °C Hot water: Up to
- ±1 °C Held to what you set: Around the temperature you set
- 24×7 Cooling and hot water: Together, all day and night
- 40% Less power*: Than a separate AC and geyser
- Cooling and hot water, together: One refrigerant circuit chills your water and heats your water at the same time. It never has to pick one.
- Cool air and warm air: Rooms from 16 to 30 °C through the same indoor units, in summer and in winter.
- Free hot water: The heat taken out of your rooms goes into the tank, up to 55 °C, instead of outside.
- Underfloor and pool: Heating or cooling for underfloor circuits, pools and large water bodies.
- Fast cooling: Chilled water is stored, so cold is ready the moment you are.
- Twin built-in pumps: One runs the cold circuit, one the hot. A standard VRF has no water pumps at all.
- Safe mode, not breakdown: It protects itself from pressure, freezing, overload and short circuits, and checks itself at every start.
- Only water inside your home: The refrigerant stays sealed in the outdoor unit. No gas inside your home.
*Savings depend on how much cooling and hot water you use together.
How it works
Cooling + hot water: Your rooms are cooled and your water is heated, at the same time.
- Warm room air heats the chilled water as it runs through the indoor units.
- AVITOR pulls that heat out of the water and sends it to the hot water tank.
- Rooms stay cool. The tank fills with free hot water.
Result: Free hot water, from heat that would have been thrown away.
Hot water ready: The tank is full but rooms still need cooling, so the extra heat goes outside.
- The hot water tank has reached its temperature.
- The controller switches its valves and the finned air coil takes over as the condenser.
- Spare heat leaves through the coil and fan. Cooling carries on without a pause.
Result: A full tank never stops your cooling.
Rooms comfortable: Rooms are comfortable but you still need hot water, so AVITOR draws heat from the air.
- Rooms are at the temperature you set, so no cooling is needed.
- The air coil now works as the evaporator and picks up heat from the outside air.
- That heat goes into the tank. Hot water, for less power than a standard geyser.
Result: Hot water on demand, even when nothing needs cooling.
Winter: In winter the same machine works the other way: hot water warms your rooms.
- AVITOR makes hot water from the outside air.
- The same indoor units that cool in summer now blow warm air, up to 30 °C.
- Hot water still reaches every bathroom and tap.
Result: Warm rooms and hot taps. One machine, all year.
Inside the machine
- 1. Compress (Compressor + 4-way valve): Raises refrigerant vapour to high pressure and high temperature. The 4-way reversing valve routes it. In plain words: It squeezes the gas until it is hot.
- 2. Condense (Shell & tube condenser + hot water tank): Hot gas condenses to liquid and hands its heat to the water. In plain words: That heat becomes your hot water, up to 55 °C.
- 3. Expand (Liquid receiver + expansion valve): The receiver buffers the refrigerant charge; the electronic expansion valve (EEV) drops the pressure. In plain words: Squeezed through a tiny gap, the liquid turns ice-cold.
- 4. Evaporate (Shell & tube evaporator): Refrigerant evaporates, absorbing heat from the water; the vapour returns to the compressor. In plain words: It pulls heat out of the water: chilled water at 7 °C for the indoor units.
- 5. Release (Finned air coil + axial fan + PLC): Hot tank satisfied: the PLC switches the solenoid valves (SV1/SV2) and the air coil becomes the condenser. In heating mode it works the other way. In plain words: Spare heat goes to the outside air. Need more hot water? It pulls heat from the air instead.
AVITOR vs a standard VRF
- Cool air: standard VRF yes, AVITOR yes
- Warm air: standard VRF no, AVITOR yes
- Hot water: standard VRF no, AVITOR yes
- Chilled water: standard VRF no, AVITOR yes
- Underfloor heating / cooling: standard VRF no, AVITOR yes
- Pool heating / cooling: standard VRF no, AVITOR yes
- Twin pumps, hot and cold: standard VRF no, AVITOR yes
No gas inside your home. The refrigerant stays sealed in the outdoor unit. A leak is a wet patch you can see, not gas escaping unseen.
Who it is for
Homes (1500 sq ft and up)
Cool air, warm air and hot water from one machine. No outdoor units crowding your walls and no separate water heaters anywhere.
- Cool air and hot water together
- Warm air in winter
- Underfloor heating and cooling
Hospitality (Hotels, resorts, spas, restaurants)
Cooling and hot water together, with pool heating and cooling from the same machine.
- Cool air and hot water together
- Pool heating and cooling
- Twin built-in pumps for large water bodies
Healthcare (Hospitals)
Cooling and hot water, 24×7. It protects itself with safe mode, and one fault never shuts everything down: close one valve and every other room keeps running.
- 24×7 cooling and hot water
- Safe mode, not breakdown
- Close one valve, every other room keeps running
Commercial (Offices and commercial buildings)
Cooling and hot water together, with 24×7 service on one number and a 3-year comprehensive warranty.*
- Cool air and hot water together
- 24×7 service on one number
- 3-year comprehensive warranty*
Industry (Pharma, dairy, process plants)
Chilled water down to 7 °C and hot water up to 55 °C from one machine.
- Chilled and hot water together
- Anti-corrosive coil, built for harsh climates
- Any trained technician can repair it
Defence (Barracks, messes, camps)
Cooling and hot water together, with standard parts that any trained technician can repair.
- Cool air and hot water together
- Any trained technician can repair it
- Built for harsh climates
We work with homeowners, builders, developers, project consultants, channel partners.
The range
| Model | Cooling kW | Hot water kW | Power in kW | COP cool / heat | Both at once (TER) | Size L x D x H mm |
|---|
| 3 TR | 12.2 | 16.0 | 3.8 | 3.21 / 4.21 | 7.4 | 990 × 460 × 965 |
| 5 TR | 20.0 | 26.4 | 6.4 | 3.13 / 4.13 | 7.3 | 990 × 460 × 1270 |
| 8 TR | 30.0 | 39.0 | 9.0 | 3.33 / 4.33 | 7.7 | 1250 × 460 × 1600 |
| 12 TR | 50.0 | 65.5 | 15.5 | 3.23 / 4.23 | 7.5 | on request |
| 16 TR | 55.0 | 71.8 | 16.8 | 3.27 / 4.27 | 7.5 | on request |
Each kW of power returns over 7 kW of cooling and hot water together. Cooling: chilled water 12 °C in, 7 °C out. Heating: condensing at 55 °C, water ΔT 5 °C. Flow rates quoted at 27 °C.
Our commitment
- 24×7 technical support: Our technicians are alerted the moment a fault happens. You see it in your app too.
- Safe mode, not breakdown: It protects itself from pressure, freezing, overload and short circuits, and checks itself at every start.
- Any technician can repair it: Standard parts. Any trained technician can service it.
- One fault never shuts the house: Close one valve and every other room keeps running.
- Built for harsh climates: Anti-corrosive coil and twin built-in pumps.
3-year comprehensive warranty.* Parts and labour, with 24×7 service on one number. Our commitment to you beyond the sale. Terms and conditions apply.
Next step
- 1. Site visit: We look at your home.
- 2. Your numbers: Cooling and hot water, worked out.
- 3. Your proposal: In writing.
Jivo Smart Climtech Solutions Pvt. Ltd. (AVITOR), A701, 7th Floor, Integrated Arcade (Karma Siddhi), RB Mehta Marg, Patel Chowk, Ghatkopar (E), Mumbai 400077. hetavi@jivoscs.com · +91 98201 12340 · +91 91526 13999